Caution: The ultrasonic sensor is a one time use component. If the
ultrasonic sensor is removed, a new ultrasonic sensor must be installed.
-
Attach the 22 mm tip to the force gauge.
-
Connect the electrical connector to a new ultrasonic sensor.
-
Ensure that there is sufficient slack in the electrical harness to prevent it
from pulling on the sensor when it is installed. Reposition the harness as
necessary.
-
Use alcohol wipes to clean the sensor mounting area on the door panel.
Caution: The ultrasonic sensor and door panel must be at an elevated
temperature for proper adhesion. Read this section fully before continuing.
Perform steps 5-10 without stopping.
-
Use an infrared thermometer to check the temperature of the door panel. If
necessary, use the heat gun to heat the door panel to at least 25 degrees C (77
degrees F).
Caution: Do not
continue this procedure unless the door panel is at least 25 degrees C (77
degrees F).
-
Use a spring clamp, bar clamp, or similar tool to gently hold the sensor with
the coupling tape facing up.
-
Aim the infrared thermometer at the face of the ultrasonic sensor. Use the heat
gun to heat the face of the ultrasonic sensor to 45 degrees C (113 degrees
F).
Warning: Wear
heat-resistant gloves when performing this operation.
-
Remove the protective film from the coupling tape on the new sensor.
-
Install the ultrasonic sensor.
-
Use the force gauge to apply a force of 55 N to the sensor for at least 10
seconds.
-
Reinstall all components that were removed for access.
Note: When reinstalling the spacer, ensure that the flat side faces the
sensor.