Caution: The ultrasonic sensor is a one time use component. If the
               ultrasonic sensor is removed, a new ultrasonic sensor must be installed.
          
         - 
               Attach the 22 mm tip to the force gauge.
            
 
- 
               Connect the electrical connector to a new ultrasonic sensor.
            
 
- 
               Ensure that there is sufficient slack in the electrical harness to prevent it
                  from pulling on the sensor when it is installed. Reposition the harness as
                  necessary.
            
 
- 
               Use alcohol wipes to clean the sensor mounting area on the door panel.
            
 
               
Caution: The ultrasonic sensor and door panel must be at an elevated
                  temperature for proper adhesion. Read this section fully before continuing.
                  Perform steps 5-10 without stopping. 
            - 
               Use an infrared thermometer to check the temperature of the door panel. If
                  necessary, use the heat gun to heat the door panel to at least 25 degrees C (77
                  degrees F).
               
                  Caution: Do not
                     continue this procedure unless the door panel is at least 25 degrees C (77
                     degrees F).
                
             
- 
               Use a spring clamp, bar clamp, or similar tool to gently hold the sensor with
                  the coupling tape facing up.
            
 
- 
               Aim the infrared thermometer at the face of the ultrasonic sensor. Use the heat
                  gun to heat the face of the ultrasonic sensor to 45 degrees C (113 degrees
                  F).
               
                  Warning: Wear
                     heat-resistant gloves when performing this operation.
                
             
- 
               Remove the protective film from the coupling tape on the new sensor.
            
 
- 
               Install the ultrasonic sensor.
            
 
- 
               Use the force gauge to apply a force of 55 N to the sensor for at least 10
                  seconds.
            
 
- 
               Reinstall all components that were removed for access. 
               
                  Note: When reinstalling the spacer, ensure that the flat side faces the
                     sensor.