Caution: Ensure that the
               vehicle is not charging while performing this procedure.
         - 
            Open the hood.
         
- 
            Connect a laptop with Toolbox to the vehicle.
            
               Tip: The HEPA filter can be removed while waiting for Toolbox to
                  open. 
 
- 
            Open .
         
- 
            In the "Fluid Drain and Refill" panel, set the "Routine" to Start Fluid
                  Drain/Fill then click the Start/Play
               button.
         
- 
            Open .
         
- 
            In the "Thermal Systems Signals" panel, ensure that the system is in "Series
               Mode".
            
               Note: Do not continue this procedure until the vehicle is in "Series Mode". 
 
- 
            Remove the HEPA filter housing (refer to
                  procedure).
         
- 
            Remove the coolant reservoir cap.
         
- 
            Add coolant to the "MAX" line.
         
- 
            In the "Fluid Drain and Refill" panel, set the "Routine" to Stop Fluid
                  Drain/Fill then click the Start/Play
               button.
         
- 
            Open . Click the Start/Play button.
         
- 
            While the coolant air purge procedure is running, add coolant as needed so that the
               reservoir remains filled at the "MAX" line.
            
               Note: The coolant air purge procedure takes approximately 15 minutes. 
 
- 
            Reinstall all components that were removed for access.
         
- 
            Disconnect Toolbox from the vehicle.