Actuator - Driver's Temperature (Remove and Replace)

FRT No: 18102102

Removal

  1. Remove IP carrier (refer to procedure)
  2. Disconnect duct temperature sensor harness connector.
  3. Remove screw securing duct to HVAC assembly and position duct aside (torque 1 Nm).
  4. Disconnect actuator harness connector.
  5. Remove screws (x3) securing driver's footwell actuator to HVAC assembly (torque 1 Nm).
  6. Remove driver temperature door flap actuator.
    Caution: Take care not to damage component(s).

Installation