Open the front trunk.
-
Turn off the climate control system.
-
Fully open the driver's window.
-
Close all doors.
-
Remove the underhood storage unit (refer to
procedure).
Warning: If the 12V power supply is disconnected, do not attempt to open any doors with door glass in closed position. Failure to follow this instruction could result in door glass shatter.
Note: Before disconnecting the 12V power supply, ensure that the
driver’s door window is fully open. Failure to follow this instruction could
result in vehicle lockout.
-
Disconnect the 12V battery ground connection (torque 5 Nm).
-
Disconnect the first responder loop (X536). Do not cut the loop.
-
Wait at least 2 minutes for all electrical circuits to fully discharge.
Warning: Before working on any high voltage components, perform the
Electrical Isolation Procedure
(refer to
procedure).