Pipe - High Pressure - Sub-Cool Condenser to Chiller (Remove and Replace)

FRT No: 18204002

Removal

  1. Recover refrigerant from the vehicle (refer to procedure)
  2. Remove front skid plate (refer to procedure)
  3. Remove nut (x1) securing pipe to sub-cool condenser (torque 8 Nm).
  4. Remove nut (x1) securing pipe retaining plate to TXV (torque 12 Nm).
  5. Disconnect refrigerant pipes from TXV.
    Caution: Plug pipe connections to prevent ingress of moisture or dirt.
    Caution: Remove and discard O-rings.
  6. Remove underhood storage unit for access (refer to procedure)
  7. Remove bolt securing sub-cool condenser / chiller high pressure pipe at union to high pressure charge port pipe (torque 8 Nm).
    Caution: Plug pipe connections to prevent ingress of moisture or dirt.
    Caution: Remove and discard O-rings.
  8. Maneuver and remove pipe.

Installation

  1. Installation procedure is the reverse of removal, except for the following:
  2. Replace A/C pipe O-rings.
    Caution: Lubricate new O-rings with clean refrigerant oil.